Q-2, r. 35.5 - Regulation respecting landfill methane reclamation and destruction projects eligible for the issuance of offset credits

Full text
26. Every landfill gas flow meter and CH4 analyzer used by the promoter to quantify the GHG emission reductions attributable to the project must measure
(1)  the flow of landfill gas before it is sent to the reclamation or destruction device, continuously and recorded every 15 minutes or totalized and recorded at least daily, adjusted for temperature and pressure; and
(2)  the CH4 concentration of the landfill gas sent to the reclamation or destruction device, continuously, recorded every 15 minutes and totalized as a daily average.
When temperature and pressure must be measured to correct flow values at standard conditions, the parameters must be measured continuously.
M.O. 2021-06-11, s. 26.
In force: 2021-07-15
26. Every landfill gas flow meter and CH4 analyzer used by the promoter to quantify the GHG emission reductions attributable to the project must measure
(1)  the flow of landfill gas before it is sent to the reclamation or destruction device, continuously and recorded every 15 minutes or totalized and recorded at least daily, adjusted for temperature and pressure; and
(2)  the CH4 concentration of the landfill gas sent to the reclamation or destruction device, continuously, recorded every 15 minutes and totalized as a daily average.
When temperature and pressure must be measured to correct flow values at standard conditions, the parameters must be measured continuously.
M.O. 2021-06-11, s. 26.